6330/C3VL2071 Electrically Insulated Ball Bearings

6330/C3VL2071 Electrically Insulated Ball Bearings

inner ring insulated ball bearing 6330/C3VL2071, white inner ring ceramic coating.

Reliable 6330/C3VL2071 - Global Shipping Available

$ 536 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6330/C3VL2071
  • Equivalent Interchange 6330/C3VL2071 (SKF); 6330-J20C-C3 (FAG); 6330-M-C3-SQ77E (NKE);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL2071
  • Insulating Coating Types Inner ring insulation coating
  • Manufacturers TFL
  • Bore Diameter 150.0 mm
  • Outside Diameter 320.0 mm
  • Width 65.0 mm
  • Net Weight 22.7kg
  • Basic Dynamic Load Rating 286.0 kN
  • Basic Static Load Rating 285.0 kN
  • Reference Speed 4300.0 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Sheet metal
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

6330/C3VL2071 Equivalent Interchange Brands

TFL 6330/C3VL2071 is fully interchangeable with equivalent inner-ring insulated bearings from SKF and FAG in physical geometry, rotational precision, and dielectric properties. Its “VL2071” (SKF) or “J20C” (FAG) suffix identifies the industry-standard inner-ring coating solution, enabling seamless integration into existing generator and large-scale VFD drive shaft systems. Rigorous high-voltage resistance inspection prior to delivery ensures consistent reliability in heavy-industrial MRO and wind power maintenance.

SKF FAG NKE
6330/C3VL2071 6330-J20C-C3 6330-M-C3-SQ77E

Why Choose TFL?

TFL is an integrated supplier focused on the field of industrial electrically insulated bearings. Leveraging a robust supply chain network and a strict ISO 9001 quality monitoring system, we are committed to providing global clients with large rolling bearings of equivalent electromagnetic protection quality. Through flexible zero-MOQ support, competitive logistics lead times, and expert application selection consulting, TFL comprehensively helps enterprises reduce unplanned downtime and significantly lower procurement costs.

Inner Ring Oxide-Coated Bearings 6330/C3VL2071

Features of 6330/C3VL2071

Common Applications of Electrically Insulated Bearings

The TFL 6330/C3VL2071 large-size insulated bearing is specifically supplied for heavy-duty industrial VFD drive equipment requiring extreme load capacity and insulation reliability. Typical target fields include megawatt-class wind turbine generators, high-voltage explosion-proof motors, heavy-duty pulp refiners, and electric rotating assemblies in rail traction systems with rotating outer rings or high-frequency inverter drives.

Illustration of insulated bearing within a wind turbine generator

Wind Turbines

TFL 6330/C3VL2071 can be applied in Vestas or Siemens Gamesa 2.0MW to 3.5MW wind turbine generator systems. Since high-power generators under high-speed, variable loads produce continuous VFD surges, this model uses its 3000V inner-ring insulation layer to isolate the generator bearing housing. Having a smaller surface area than outer-ring coatings, it demonstrates superior shielding efficiency against high-frequency induced voltages.

A cutaway view of an industrial VFD motor highlighting the installation of an electrically insulated bearing to block shaft currents.

Large Industrial VFD Motors

In high-power VFD motors utilizing high-frequency PWM control, such as the Siemens 1LG4 or ABB M3BP series, the TFL 6330/C3VL2071 is highly recommended to defend against induced high-frequency voltages. The bearing's C3 clearance structure perfectly balances heat dissipation during heavy-load operation, preventing premature carbonization and deterioration of grease from electrical erosion, making it a recommended spare part for key main drive motors in paper, pharmaceutical, and chemical fertilizer industries.

Mining locomotive traction motor disassembled revealing insulated bearing on the armature shaft.

Mining & Heavy Chemical Equipment

For large-scale refiners, heavy crushers, or massive fluid transport compressors from brands like CITIC Heavy Industries, transmission shafts are prone to gathering leakage currents from static and VFD interference under severe conditions. Leveraging the ultra-high load capacity of the heavy 63 series, along with the high-strength inner-ring ceramic barrier, the TFL 6330/C3VL2071 ensures trouble-free transmission systems and isolates electrical noise in control boards caused by bearing discharges.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

What is the difference between VL2071 (inner-ring insulation) and VL0241 (outer-ring insulation)? How should I choose?

VL2071 indicates that the ceramic coating is applied to the inner ring's outer surfaces, while VL0241 indicates the coating is on the outer ring. When dealing with extremely high-frequency shaft currents, applications with rotating outer rings, or scenarios demanding high housing heat dissipation, inner-ring insulation (VL2071) is preferred. For standard motors with stationary outer rings, either is suitable, but the inner-ring insulation has a smaller capacitive area, providing better blockage against high-frequency stray currents.

The original equipment used a steel cage; does TFL provide a brass cage (M) upgrade for the 6330/C3VL2071?

Yes. As an integrated supplier, we can supply the standard 6330/C3VL2071 with a pressed steel cage, or integrate and supply the 6330M/C3VL2071 equipped with a machined brass cage for high-speed, heavy-impact operating conditions to increase safety margins.

What is the dielectric strength of TFL 6330/C3VL2071? Can it be used in humid offshore wind farms?

The TFL 6330/C3VL2071 supplied features a breakdown voltage protection of up to 3000V DC. Additionally, the coating surface is sealed with a specialized high-resistance resin that possesses excellent moisture-blocking capabilities, maintaining stable high insulation resistance even in offshore environments with high humidity and salt spray.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.