6330M/C3VL0241 Electrically Insulated Ball Bearings

6330M/C3VL0241 Electrically Insulated Ball Bearings

Coated insulated bearing 6330M/C3VL0241,bearing for motor

High-Insulation 6330M/C3VL0241 - with Proven Performance

$ 546 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6330M/C3VL0241
  • Equivalent Interchange 6330M/C3VL0241 (SKF); 6330-M-J20AA-C3 (FAG); 7MC3-6330C3 (NTN);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL0241
  • Insulating Coating Types Insulation coating on outer ring
  • Manufacturers TFL
  • Bore Diameter 150.0 mm
  • Outside Diameter 320.0 mm
  • Width 65.0 mm
  • Net Weight 25.4kg
  • Basic Dynamic Load Rating 286.0 kN
  • Basic Static Load Rating 285.0 kN
  • Reference Speed 4300.0 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Brass cage
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

6330M/C3VL0241 Equivalent Interchange Brands

The TFL 6330M/C3VL0241 bearing can directly replace equivalent brass-cage outer-ring insulated bearings from premium global brands like SKF and FAG without modifying any surrounding mechanical designs. Its “VL0241” (SKF) and “J20AA” (FAG) suffixes designate the industry-standard outer-ring ceramic barrier technology. Every bearing delivered undergoes strict insulation resistance tests to guarantee high-level functional equivalence.

SKF FAG NTN
6330M/C3VL0241 6330-M-J20AA-C3 7MC3-6330C3

Why Choose TFL?

TFL is an integrated supplier focused on supplying high-quality electrically insulated bearings for the global industrial sector. Through a refined supply chain system and strict ISO 9001 quality management, we guarantee that every product delivered meets premium standards in both precision and dielectric performance. By offering flexible support with zero MOQ, fast-turnaround logistics, and professional engineering selection advice, TFL is committed to being your trusted partner for optimizing procurement plans and reducing Total Cost of Ownership (TCO).

Features Of 6330M/C3VL0241

Common Applications of Electrically Insulated Bearings

The TFL 6330M/C3VL0241 outer-ring insulated bearing is widely supplied for heavy-duty industrial VFD drive systems where protection against strong shaft voltages is required. Typical target applications include high-power VFD traction motors, heavy paper mill dryer sections, large fossil fuel and chemical fertilizer circulation fans, and heavy-load multistage mining centrifugal pumps.

siemens motor and insulated bearing for motor

Heavy VFD Motors

TFL 6330M/C3VL0241 is suitable for ABB M3BP or Siemens 1LG4 series heavy-duty high-voltage variable-speed motors. Under high-power VFD operations, asymmetrical electromagnetic fields often generate high-frequency common-mode shaft currents. Utilizing 3000V-class outer-ring insulation and a precision-machined solid brass cage, this model demonstrates reliable physical blockage of current paths, reducing abnormal temperature rises and grease deterioration caused by electrical erosion.

The image shows the mining fans and insualted bearings

Industrial Draft Fans

In large-scale power generation, metallurgy, and chemical equipment, such as Howden or FläktGroup industrial draft fans, bearings must operate continuously under harsh temperatures and heavy vibrations. The TFL 6330M/C3VL0241 utilizes its C3 internal radial clearance to absorb thermal expansion of the shaft, while employing a robust outer-ring alumina barrier to capture electrostatic and high-frequency leakage currents, significantly extending the lifecycle of both mechanical and lubrication systems.

the image shows a petrochemical process pump and a deep groove ball bearing for pumps

Heavy-Duty Water Pumps

For large multistage high-pressure centrifugal feedwater pumps from brands like Sulzer or KSB, the TFL 6330M/C3VL0241 provides exceptional dielectric shielding. Its machined brass cage resists fatigue under constant fluid pulsations and heavy mechanical vibrations under variable speed control, and its performance safely replaces premium imported equivalent bearings to satisfy long-term operation requirements of water plants and petrochemical projects.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

For large heavy-duty bearings like the 6330M, how should I choose between outer-ring insulation (VL0241) and inner-ring insulation (VL2071)?

In most standard generators and VFD motors (where the outer ring is fixed in the housing and the inner ring rotates with the shaft), outer-ring insulation (VL0241) is the most common and convenient solution. However, in applications with severe high-frequency stray common-mode voltages or limited housing heat dissipation, inner-ring insulation (VL2071) offers superior high-frequency impedance blockage and reduced capacitive leakage currents because the inner-ring coating has a smaller surface area and lower equivalent capacitance.

Why must this bearing be paired with C3 clearance? What is the difference between C3 and Normal clearance?

Because the 6330M/C3VL0241 is typically used in heavy-load, heat-generating machinery, the rotating shaft runs much hotter than the stationary outer housing, resulting in notable thermal expansion. Standard (Normal) clearance is easily exhausted under high temperature differentials in high-power motors, leading to overloading and a sharp increase in friction. The larger C3 clearance successfully offsets this expansion differential, guaranteeing that the rolling elements move freely and smoothly even during thermal peaks.

As an integrated supplier, how does TFL guarantee that the quality of large insulated bearings matches nominal performance before delivering the 6330M/C3VL0241?

Every batch of TFL 6330M/C3VL0241 undergoes a double verification process prior to delivery. First, we perform 100% 3000V DC voltage endurance testing and megohmmeter impedance checks on the insulation coating to guarantee no dielectric breakdown occurs. Second, the bore dimensions, runout, and geometric tolerances are verified via three-coordinate measurements (CMM) to ensure precision complies with ISO standards, securing the safe and reliable operation of your equipment.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.